15.INPUT/OUTPUT OF DATA B-63943EN-1/02
- 1822 -
Alarm and message
Number Message Description
SR0001 TH ERROR A TH error was detected during reading from an input device.
The read code that caused the TH error and how many
statements it is from the block can be verified in the
diagnostics screen.
SR0002 TV ERROR An error was detected during the single–block TV error.
The TV check can be suppressed by setting TVC parameter
No. 0000#0 to “0”.
SR1805 ILLEGAL COMMAND An attempt was made to specify an illegal command during I/O
processing on an I/O device.
SR1806 DEVICE TYPE MISS MATCH An operation not possible on the I/O device that is currently
selected in the setting was specified.
This alarm is also generated when file rewind is instructed
even though the I/O device is not a FANUC Cassette.
SR1807 PARAMETER SETTING ERROR An I/O interface option that has not yet been added on was
specified.
The external I/O device and baud rate, stop bit and protocol
selection settings are erroneous.
SR1808 DEVICE DOUBLE OPENED An attempt was made to open a device that is being accessed.
- Channel 1
Number Message Description
SR0085 OVERRUN ERROR During a read by reader/punch interface 1, an overrun, parity,
or framing error occurred. The number of bits for entered data
was not matched, or baud rate setting or I/O device
specification number was incorrect.
SR0086 DR OFF During I/O process by reader/punch interface 1, the data set
ready input signal of the I/O device (DR) was OFF. Possible
causes are an I/O device not turn on, a broken cable, and a
defective printed circuit board.
SR0087 BUFFER OVERFLOW During a read by reader/punch interface 1, although a read
stop command was issued, more than 10 characters were
input. The I/O device or printed circuit board was defective.
- Channel 2
Number Message Description
SR1830 DR OFF(2) During I/O process by reader/punch interface 2, the data set
ready input signal of the I/O device (DR) was OFF. Possible
causes are an I/O device not turn on, a broken cable, and a
defective printed circuit board.
SR1832 OVERRUN ERROR(2) During a read by reader/punch interface 2, an overrun, parity,
or framing error occurred. The number of bits for entered data
was not matched, or baud rate setting or I/O device
specification number was incorrect.
SR1834 BUFFER OVERFLOW(2) During a read by reader/punch interface 2, although a read
stop command was issued, more than 10 characters were
input. The I/O device or printed circuit board was defective.