B-63943EN-1/02 1.AXIS CONTROL
- 149 -
Number Message Description
SV5138 FSSB:AXIS SETTING NOT COMPLETE The axis setting has not completed yet, in an automatic
setting mode.
SV5139 FSSB:ERROR The axis setting has not completed yet, in an automatic
setting mode.
SV5197 FSSB:OPEN TIME OUT Servo initialization has not completed successfully. It is
probable that an optical cable failed or a connection between
the amplifier and another module failed.
SV5311 FSSB:ILLEGAL CONNECTION 1. This alarm is issued if axes, whose servo axis numbers
(parameter No. 1023) are even and odd numbers, are
allocated to the amplifiers connected to the FSSBs of
different paths.
2. This alarm is issued if an attempt is made to set up for
use of the pulse modules connected to the FSSBs of
different paths. And the system did not satisfy the
requirements for performing HIGH SPEED HRV control.
Reference item
Manual name Item name
CONNECTION MANUAL
(HARDWARE)
(B-63943EN)
Connection to the servo amplifiers