B-63943EN-1/02 12.TOOL FUNCTIONS
- 1633 -
- Tool management extension function
- Customization of tool management data display
In customization of tool management data display with the tool
management extension function, tool figure number display can
be customized.
R Item Display width
12
Tool figure number (A) 3
- Protection of diverse tool information with KEY signals
With the tool management data protection signal, TKEY1
(G330#1), the input of tool shape numbers using MDI keys is
prohibited.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
13240 MT4 MT3 MT2 MT1
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Bit system common
# 0 MT1 The first cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13222 is invalid.
# 1 MT2 The second cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13227 is invalid.
# 2 MT3 The third cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13232 is invalid.
# 3 MT4 The fourth cartridge is of the:
0: Chain type.
1: Matrix type.
When this parameter is set to 1, parameter No. 13237 is invalid.