17.PMC CONTROL FUNCTION B-63943EN-1/02
- 2020 -
No. Item E
S
T
B
E
A
6
E
A
5
E
A
4
E
A
3
E
A
2
E
A
1
E
A
0
ED31 to ED16 ED15 to ED0
1 External program
number
1 0 0 0 X X X X Program number (BCD 4 digits with unsign)
2 External tool offset 1 0 0 1 X X X X Offset value (BCD 8 digits with sign *1)
3 Extended external
machine zero point
shift
1 0 1 0 axis code Shift value (BCD 8 digits with sign *1)
4 External machine
zero point shift
1 0 1 1 axis code Extended external machine
zero point shift value(binary)
-9999 to +9999 *2
Alarm set 1 1 0 0 0 0 0 0 Alarm No. (binary)
0 to 999 (0 to 4095)
Alarm clear 1 1 0 0 0 0 0 1 Alarm No. (binary)
0 to 999 (0 to 4095)
Operator message
set
1 1 0 0 0 1 0 0 message No. (binary)
0 to 999 (0 to 4095)
Operator message
clear
1 1 0 0 0 1 0 1 message No. (binary)
0 to 999 (0 to 4095)
5
Message 1 1 0 0 0 X 1 1 character(Character code)
Substitute No. of
parts required
1 1 1 0 0 0 0 0 No. of parts required
(BDC4 digits with unsign)
6
Substitute No. of
parts machined
1 1 1 0 0 0 0 1
No. of parts machined
(BDC4 digits with unsign)
NOTE
1 When bit 3 (EED) of parameter No. 6301 is set to 0,
BCD 4 digits are used.
2 By setting bit 7 (EEX) of parameter No. 6300 to 1, a
shift value of ±0 to 999999999 can be specified using
ED0 to ED31.