B-63943EN-1/02 2.PREPARATIONS FOR OPERATION
- 373 -
Cutting feed signal CUT<Fn002#6>
[Classification] Output signal
[Function] Signals that cutting feed is being performed by automatic operation.
[Output condition] This signal is set to 1 in the following case:
- When cutting feed is being performed by automatic operation
(cutting feed for linear interpolation, circular interpolation,
helical interpolation, thread cutting, skip cutting, or cutting in
canned cycle)
CAUTION
This signal is not set to "1" in the feed hold state.
NOTE
This signal is set to "1" even when the feedrate
override is 0%, and even during interlock.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Fn002 CUT RPDO