1.AXIS CONTROL B-63943EN-1/02
- 40 -
8570
Controlled axis for which the first high-speed position switch function is
performed
to
8579
Controlled axis for which the tenth high-speed position switch function is
performed
12201
Controlled axis for which the eleventh high-speed position switch function is
performed
to
12206
Controlled axis for which the sixteenth high-speed position switch function
is performed
[Input type] Parameter input
[Data type] Byte path
[Valid data range] 1 to number of controlled axes
Each of these parameters sets a controlled axis number for which each
of the first to sixteenth high-speed position switch functions is
performed.
Set 0 for the number corresponding to a high-speed position switch
which is not to be used.
NOTE
Parameters No. 8576 to 8579 and No. 12201 to
12206 are valid only when EHP (bit 7 of parameter
No. 8500) is 1.
8580 Maximum value of the operation range of the first high-speed position switch
to
8589
Maximum value of the operation range of the tenth high-speed position
switch
12221
Maximum value of the operation range of the eleventh high-speed position
switch
to
12226
Maximum value of the operation range of the sixteenth high-speed position
switch
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm, inch, degree (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] 9 digit of minimum unit of data (refer to standard parameter setting
table (A) )
(When the increment system is IS-B, -999999.999 to +999999.999)
Each of these parameters sets the maximum value of the operation
range of each of the first to sixteenth high-speed position switches. If
such a setting that maximum value < minimum value is made, no
operation range exists, so that the high-speed position switch does not
operate.