B-63943EN-1/02 7.FEEDRATE CONTROL/ACCELERATION AND DECELERATION CONTROL
- 743 -
NOTE
1 Always specify G08 and G05 in an independent
block.
2 G05 can be specified only for AI contour control II.
3 The AI contour control mode is also canceled by a
reset.
4 Valid functions are limited depending on the
command format. For details, see the description
of "Valid functions".
Explanation
- Valid functions
The functions listed below are valid in the AI contour control mode.
Valid functions are limited depending on the command format and
whether AI contour control I or II is used.
Function AI contour control I AI contour control II
AI contour control II with
high-speed processing
Number of blocks read
ahead
30
(When G8 is specified:
1)
200
(When G8 is specified:
1)
600 *1
(When G8 is specified: 1)
Look-ahead
acceleration/deceleration
before interpolation
Linear or bell-shaped
acceleration/deceleration
Linear or bell-shaped
acceleration/deceleration
Linear or bell-shaped
acceleration/deceleration
Speed control with feedrate
difference on each axis
Enabled Enabled Enabled
Speed control with
acceleration in circular
interpolation
Enabled Enabled Enabled
Speed control with
acceleration on each axis
Enabled
(When G8 is specified:
Not enabled)
Enabled
(When G8 is specified:
Not enabled)
Enabled
(When G8 is specified:
Not enabled)
Smooth speed control
Not enabled
Enabled
(When G8 is specified:
Not enabled)
Enabled
(When G8 is specified:
Not enabled)
Speed control with cutting
load
Not enabled Enabled Enabled
Disregard of feedrate
command
Not enabled Enabled Enabled
*1 The number of blocks can optionally be expanded to 1000 blocks.