8.MULTI-PATH CONTROL B-63943EN-1/02
- 954 -
Signal
There are three signal types, which are selected with appropriate
parameter settings.
Parameter MPM
(No.3703#2(
Parameter 2P2
(No.3703#0
Signal type
0 0 Signal type A
0 1 Signal type B
1 0/1 Signal type C
- Signal type A
Path spindle command selection signal SLSPA <Gn063#2>
[Classification] Input signal
[Function] This signal specifies the path of the program commands to be effective
to the spindles belonging to path 1.
[Operation]
Signal input
SLSPA<Gn063#2>
Program command to be effective to the spindle
belonging to path m (= n + 1)
0 Spindle command of path 1
1 Spindle command of path 2
Path spindle feedback selection signal
[Function] You need not control the path spindle feedback selection signal
because the spindle feedback signal of path 1 is always effective to
paths 1 and 2.