2.PREPARATIONS FOR OPERATION B-63943EN-1/02
- 386 -
#7 #6 #5 #4 #3 #2 #1 #0
2215
BDSW
[Input type] Parameter input
[Data type] Bit axis
# 5 ABDSW The Unexpected disturbance torque detection function for a specified
axis:
0: Cannot be disabled.
1: Can be disabled.
- Parameters for spindle
#7 #6 #5 #4 #3 #2 #1 #0
4015 SPLDMT
[Input type] Parameter input
[Data type] Bit spindle
# 1 SPLDMT SPLDMT Spindle load torque monitor function
0: The spindle load torque monitor function is disabled.
1: The spindle load torque monitor function is enabled.
4247 Magnetic flux compensation time constant for spindle load torque monitor
[Input type] Parameter input
[Data type] Word spindle
[Unit of data] msec
[Valid data range] 0 to 8192
This parameter is used to compensate the delay in the generation of
magnetic flux in the spindle motor relative to the specified value.
When 0 is set, it is assumed that the generation of magnetic flux is not
delayed.
Standard setting depends of the motor model.
4248 Spindle load torque monitor constant
[Input type] Parameter input
[Data type] Word spindle
[Valid data range] 0 to 32767
This constant is determined by the maximum output torque and inertia
of the motor. It is used for observer processing.
Standard setting depends of the motor model.
4249 Observer gain 1 for spindle load torque monitor
[Input type] Parameter input
[Data type] Word spindle
[Valid data range] 0 to 32767
Standard setting is 500.