B-63943EN-1/02 5.AUTOMATIC OPERATION
- 575 -
Number Message Description
PS0095 P TYPE NOT ALLOWED (EXT OFS
CHG)
P type cannot be specified when the program is restarted. (After
the automatic operation was interrupted, the external workpiece
offset amount changed.) Perform the correct operation according
to the User's manual.
PS0096 P TYPE NOT ALLOWED (WRK OFS
CHG)
P type cannot be specified when the program is restarted. (After
the automatic operation was interrupted, the workpiece offset
amount changed.) Perform the correct operation according to the
User's manual.
PS0097 P TYPE NOT ALLOWED (AUTO
EXEC)
P type cannot be directed when the program is restarted. (After
power ON, after emergency stop or alarms PS0094 to 0097
reset, no automatic operation is performed.) Perform automatic
operation.
PS0098 G28 FOUND IN SEQUENCE
RETURN
A command of the program restart was specified without the
reference position return operation after power ON or emergency
stop, and G28 was found during search. Perform the reference
position return.
PS0099 MDI EXEC NOT ALLOWED AFT.
SEARCH
After completion of search in program restart, a move command
is given with MDI.
Warning
WARNING
As a rule, the tool cannot be returned to a correct position under the following
conditions.
Special care must be taken in the following cases since none of them cause an
alarm:
- Manual operation is performed when the manual absolute mode is OFF.
- Manual operation is performed when the machine is locked.
- When the mirror image is used. However, P type return is possible for a block
that switched between ON and OFF most recently or a subsequent block. In this
case, the mirror image signal status present when the program was interrupted
must be maintained.
- When no coordinate system is set up at the beginning of a program in which main
commands are executed in the incremental mode.
- When manual operation is performed in the course of axis movement for
returning operation.
- When the program restart is commanded for a block between the block for skip
cutting and subsequent absolute command block.
- When program restart is specified in the machine lock state, then the machine
lock is canceled.
- When program restart specified for an intermediate block for a multiple repetitive
canned cycle
- In general, when a coordinate system is set up, changed, or shifted after the
search operation ends, the tool cannot be returned to a correct position.