B-63943EN-1/02 12.TOOL FUNCTIONS
- 1577 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3115 APL
[Input type] Parameter input
[Data type] Bit axis
# 5 APL When the active offset value change mode based on manual feed is
selected, the relative position indication is automatically:
0: Not preset.
1: Preset.
This parameter is used to restore an offset value changed in the active
offset value change mode to the original value. An offset value can
be restored to the original value by making a movement on the axis by
manual feed so that the relative position indication (counter) is set to a
position of 0.
#7 #6 #5 #4 #3 #2 #1 #0
5000 ASG
[Input type] Parameter input
[Data type] Bit path
# 3 ASG When offset memory B or C is used, the offset value to be changed
with the active offset value change function based on manual feed is:
0: Geometry compensation value
1: Wear compensation value
NOTE
This parameter is valid when offset memory B or C is
used.
#7 #6 #5 #4 #3 #2 #1 #0
5040 MOF
[Input type] Parameter input
[Data type] Bit
# 2 MOF As the DI/DO signals for the active offset value change function based
on manual feed:
0: G297#4, G297#5, G297#6, and F297#5 are used.
1: G203#4, G203#5, G203#6, and F199#5 are used.