1.AXIS CONTROL B-63943EN-1/02
- 268 -
# 3 ART The retract function executed when a servo spindle alarm is issued is:
0: Disabled.
1: Enabled.
#7 #6 #5 #4 #3 #2 #1 #0
7703 ARO ARE ERV
[Input type] Parameter input
[Data type] Bit path
# 0 ERV During EGB synchronization (G81), feed per revolution is performed
for:
0: Feedback pulses.
1: Pulses converted to the speed for the workpiece axis.
# 1 ARE The retract function executed when a servo spindle alarm is issued
retracts the tool during:
0: EGB synchronization or automatic operation (automatic
operation signal OP = 1).
1: EGB synchronization.
# 2 ARO The retract function executed when a servo spindle alarm is issued
retracts the tool during:
0: EGB synchronization.
1: EGB synchronization and automatic operation (automatic
operation signal OP = 1).
The following table lists the parameter settings and corresponding
operation.
ARE ARO Operation
1 0 During EGB synchronization
1 1
During EGB synchronization and
automatic operation
0 0
0 1
During EGB synchronization or
automatic operation
NOTE
1 Parameters ARE and ARO are valid when bit 3
(ART) of parameter No. 7702 is set to 1 (when the
retract function executed when a servo spindle
alarm is issued is enabled).
2 This parameter is valid when bit 1 (ARE) of
parameter No. 7703 is set to 1.