B-63943EN-1/02 2.PREPARATIONS FOR OPERATION
- 371 -
NOTE
8 Invalid mode selection signals
When mode selection signals MD4, MD2, and
MD1 are set to 0, 1, and 0, respectively, the mode
before the signals are changed is selected. When
MD4, MD2, and MD1 have been set to 0, 1, and 0,
respectively, since power-on, the MDI mode is
selected.
9 Notes on output signals
1) When parameter JHD is set to 1:
In the jog feed mode, the output signals are set
as follows:
MJ=1, MH=0
In the manual handle feed mode, the output
signals are set as follows:
MH=1, MINC=0
10 Other notes
The manual handle feed function is an option.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
7100 JHD
[Input type] Parameter input
[Data type] Bit path
# 0 JHD Manual handle feed in JOG feed mode or incremental feed in the
manual handle feed
0: Invalid
1: Valid