B-63943EN-1/02-01
Edit
Apprv.
Design
Sheet
Title
Draw
No.
10/126
Date
Design
Descri
tion
Date
FANUC Se
ies 30i/31i/32i-
, 31i-
5
PMC Axis Control
2004.10.7
Group-by-
group
signal
Input signal (G) address Output signal (F) address
Group 28 G6150#0,1,6,7 F6129#5,7
Group 29 G7150#0,1,6,7 F7129#5,7
Group 30 G7150#0,1,6,7 F7129#5,7
Group 31 G7150#0,1,6,7 F7129#5,7
Group 32 G7150#0,1,6,7 F7129#5,7
Group 33 G8150#0,1,6,7 F8129#5,7
Group 34 G8150#0,1,6,7 F8129#5,7
Group 35 G8150#0,1,6,7 F8129#5,7
Group 36 G8150#0,1,6,7 F8129#5,7
Group 37 G9150#0,1,6,7 F9129#5,7
Group 38 G9150#0,1,6,7 F9129#5,7
Group 39 G9150#0,1,6,7 F9129#5,7
Group 40 G9150#0,1,6,7 F9129#5,7
A path-by-path signal is input/output to and from a signal of the path to which the group
belongs (for example, path 1 when a command is issued from group 1). No path-by-path
signal is input/output to and from the path to which the axis assigned to the group belongs.
In Fig. 1.1.1 (e) Relationships between paths and groups for path-by-path signals (G, F),
for example, the signal EBUFB#2 (described later) input from group 5 (whose signal
addresses are allocated to path 2) is output to EOV#2 (path-by-path signal described later)
of path 2 to which group 5 addresses are allocated.
EBUFB#2 is not output to EOV#1 of path 1, to which the first axis assigned to group 5
belongs.
Path 2
Path 1
PMC CNC
Group 5 command
Group 5
(Signal
addresses are
allocated to path
2.)
DI / DO
First axis control
Second axis control
Group 1
(Signal
addresses are
allocated to path
1.)
Path-by-path signal
EOV#1
Path-by-path signal
EOV#2
Fig. 1.1.1 (e) Relationships between paths and groups for path-by-path signals (G, F)