11.SPINDLE SPEED FUNCTION B-63943EN-1/02
- 1382 -
- Display of spindle position data
Position coder signal pulse data from the spindle one-rotation signal is
displayed.
- Position coder signal pulse data of the first spindle → Diagnosis
No.445
- Position coder signal pulse data of the second spindle →
Diagnosis No.446
- Position coder signal pulse data of the third spindle → Diagnosis
No.447
- Position coder signal pulse data of the fourth spindle →
Diagnosis No.448
NOTE
1 For an unconnected spindle, 0 is displayed.
2 For display of this data, the conditions below must
be satisfied.
<1> Bit 1 (SPPOS) of parameter No. 3117 must be
set to 1.
<2> A compliant spindle amplifier must be used.
<3> Compliant spindle control software must be
used.
<4> The state where the serial spindle has
detected a one-rotation signal must be set.
To detect a one-rotation signal accurately, spindle
orientation must be performed. This orientation
operation needs to be performed only once after
the power is turned on.
Whether a one-rotation signal has been detected
can be known by checking the serial spindle state
signals (PC1DEA to PC1DED).
Diagnosis display
- Spindle position data
0445 SPINDLE POSITION DATA (1st SPINDLE)
0446 SPINDLE POSITION DATA (2nd SPINDLE)
0447 SPINDLE POSITION DATA (3rd SPINDLE)
0448 SPINDLE POSITION DATA (4th SPINDLE)
Position coder signal pulse data from the spindle one-rotation signal of
each spindle
[Unit] Pulse
- Spindle position deviation
0450 SPINDLE MOTION ERROR
Spindle position deviation during rigid tapping
[Unit] Pulse