B-63943EN-1/02 16.MEASUREMENT
- 1853 -
WARNING
1 SKIP6 to SKIP8 are at the same addresses as skip
signal ESKIP (axis control by PMC) and
measurement position arrival signal XAE and ZAE
(tool length automatic measurement). Be careful
when using both. (T series)
2 SKIP2 and SKIP6 to SKIP8 are at the same
addresses as skip signal ESKIP (axis control by
PMC) and measurement position arrival signal
XAE, YAE, and ZAE (tool length automatic
measurement). Be careful when using both. (M
series)
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
3008 XSG
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 2 XSG A signal assigned to an X address is:
0: Fixed at the address.
1: Able to be reassigned to an arbitrary X address.
NOTE
When this parameter was set to 1, parameters No.
3013, No. 3014, No. 3012, and No. 3019 must be
set. If parameters No. 3013 and No. 3014 are not
set, the reference position return deceleration
signal is assigned to bit 0 of X0000. If parameters
No. 3012 and No. 3019 are not set, the skip to X0
signal, PMC axis control skip signal, measurement
position arrival signal, axis-direction-specific
manual feed interlock signal, and tool
compensation write signal are assigned to X0000.