17.PMC CONTROL FUNCTION B-63943EN-1/02
- 1938 -
NOTE
5 If the axis control temporary stop signal ESTPg is
set to 1 for a group placed in the simultaneous
start mode, a gradual stop occurs on the controlled
axes of all groups placed in the simultaneous start
mode.
6 If the block stop signal ESBKg is set to 1 for a
group placed in the simultaneous start mode, axis
control stops when the execution of blocks for all
groups in the simultaneous start mode is
completed. However, if the block stop disable
signal EMSBKg of the command block is set to 1
for a group placed in the simultaneous start mode,
the block stop signal ESBKg is invalid.
7 When specifying the simultaneous start mode on
command, check that the buffer full signal
EABUFg is set to 0 for all specified groups.
8 If a group with no axis selected using parameter
No. 8010 and the control axis selection signals
EAX1 to EAX8 is selected as a simultaneous start
group, the simultaneous start mode command is
ignored.
9 If the simultaneous start mode is specified for a
group already placed in the simultaneous start
mode, the specification is ignored.
10 When any of the groups in the simultaneous start
mode is placed in the overtravel state, the other
groups also stop. When the overtravel state of the
group is released, the other groups also restart
operation.
11 When ordinary commands are specified, three
blocks are buffered. In the simultaneous start
mode, however, only one block is buffered.
12 If the simultaneous start mode off command is
specified when a command is buffered in the
simultaneous start mode, the buffered command
for each group is executed.
Notes on the commands
- Display of the remaining amount of travel
When the continuous feed command (EC0g to EC6g: 06h) and the
external pulse synchronization commands (EC0g to EC6g: 0Bh, 0Dh
to 0Fh) are specified, the remaining amount of travel indicates 0 at all
times.