1.AXIS CONTROL B-63943EN-1/02
- 212 -
NOTE
3 During synchronous operation, the axis-by-axis
signals such as for external deceleration, interlock,
and machine lock are enabled for the master axis
only. During synchronous operation, those signals
for the slave axis are ignored.
4 When switching the synchronization state in a
program, be sure to specify M codes (parameter
No. 8337 and No. 8338) for turning synchronization
on and off. By switching between the input signals
SYNCx (G138) and SYNCJx (G140) from the PMC
with the M codes, the synchronization state can be
switched in the program.
5 When controlled axis removal is performed, the
synchronization state is cancelled. When
performing controlled axis removal, perform
removal for the master axis and slave axis at the
same time.
6 If a programmed command is specified for the
slave axis during synchronous operation, an alarm
(PS0213) is issued.
A programmed command can be specified for the
slave axis when switching between synchronous
operation and normal operation is set to 0 (with bit
5 (SCA) of parameter No. 8304 set to 0) to select
normal operation.
7 Feed axis synchronization control and PMC axis
control cannot be used at the same time.
8 Feed axis synchronization control cannot be used
with an axis for which three-dimensional coordinate
conversion is enabled.
Reference item
Manual name Item name
USER’S MANUAL
(B-63944EN)
Feed axis synchronous control