B-63943EN-1/02 1.AXIS CONTROL
- 45 -
#7 #6 #5 #4 #3 #2 #1 #0
8508 D08 D07 D06 D05 D04 D03 D02 D01
8509 D16 D15 D14 D13 D12 D11 D10 D09
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
D01 to D16 The output type of corresponding high-speed position switch is:
0: Normal.
1: Decision by direction.
#7 #6 #5 #4 #3 #2 #1 #0
8512 A08 A07 A06 A05 A04 A03 A02 A01
8513 A16 A15 A14 A13 A12 A11 A10 A09
[Input type] Parameter input
[Data type] Bit path
A01 to A16 The corresponding high-speed position switch is set to ON when the
coordinate where the switch is set to ON has been passed:
0: In - direction.
1: In + direction.
#7 #6 #5 #4 #3 #2 #1 #0
8516 B08 B07 B06 B05 B04 B03 B02 B01
8517 B16 B15 B14 B13 B12 B11 B10 B09
[Input type] Parameter input
[Data type] Bit path
B01 to B16 The corresponding high-speed position switch is set to OFF when the
coordinate where the switch is set to OFF has been passed:
0: In - direction.
1: In + direction.
WARNING
1 Be sure not to use any Y signal already used in the
PMC ladder with this function. If used, the
machine may behave in an unexpected manner.
2 If you want to use high-speed position switches for
multiple paths, use a different Y signal output
address for each path.