B-63943EN-1/02-08
Title
Draw
No.
Ed. Date Design Description
Date Design. Apprv.
6/20
page
FANUC Series 30i/300i/300is-MODEL A
FANUC Series 31i/310i/310is-MODEL A5
FANUC Series 31i/310i/310is-MODEL A
FANUC Series 32i/320i/320is-MODEL A
The addition of MANUAL HANDLE FEED 4/5-units FUNCTION
(The correction of CONNECTION MANUAL(FUNCTION))
Upper limit of the feedrate in manual handle feed
The upper limit of the feedrate is determined as follows depending on the
input signal (maximum manual handle feedrate switch signal HNDLF)
from PMC.
・ If HNDLF is 0, clamping is performed at the manual rapid traverse
rate (parameter No. 1424).
・ If HNDLF is 1, clamping is performed at the rate set in parameter
No.1434.
Movement direction of an axis to the rotation of MPG
Parameter HNGx (No. 7102 #0) switches the direction of MPG in which
the tool moves along an axis, corresponding to the direction in which the
handle of the manual pulse generator is rotated.
This parameter is valid only for the following functions.
・ Manual handle feed
・ Manual handle interruption
Warning
△
! WARNING
Rotating the handle quickly with a large magnification
such as ×100 moves the tool too fast. The feedrate
is clamped at the rapid traverse feedrate.
Note
NOTE
Rotate the manual pulse generator at a rate of 5
rotations per second or lower. If the manual pulse
generator is rotated at a rate higher than five rotations
per second, the tool may not stop immediately after
the handle is no longer rotated or the distance the tool
moves may not match the graduations on the manual
pulse generator.