5.AUTOMATIC OPERATION B-63943EN-1/02
- 564 -
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
6000 SBV SBM
[Input type] Parameter input
[Data type] Bit path
# 5 SBM Custom macro statement
0: Not stop the single block
1: Stops the single block
If you want to disable the single blocks in custom macro statements
using system variable #3003, set this parameter to 0. If this parameter
is set to 1, the single blocks in custom macro statements cannot be
disabled using system variable #3003. To control single blocks in
custom macro statements using system variable #3003, use bit 7
(SBV) of parameter No. 6000.
# 7 SBV Custom macro statement
0: Not stop the single block
1: Enable/disable single block stop with system variable #3003
Parameter SBM (No.6000#5)
0 1
0
Disables single block stop.
Parameter
SBV
(No.6000#7)
1
Enables single block stop.
(With variable #3003,
single block stop can be
enabled/disabled.)
Enables single block stop.
(With variable #3003, single
block stop cannot be
enabled/disabled. Single block
stop is enabled at all times.)
CAUTION
CAUTION
1 Operation in thread cutting
When the SBK signal turns to "1" during thread cutting,
operation stops after execution of the first non-thread
cutting block after the thread cutting command.
2 Operation in canned cycle
When the SBK signal turns to "1" during canned cycle
operation, the operation stops at each positioning,
approach, drilling and retreat instead of the end of the
block. The SPL signal turns to "1" while the STL signal
turns to "0", showing that the end of the block has not
been reached. When the execution of one block is
completed, the STL and SPL signals turn to "0" and
the operation is stopped.
Reference item
Manual name Item name
USER’S MANUAL
(B-63944EN)
Single block