B-63943EN-1/02 16.MEASUREMENT
- 1861 -
#7 #6 #5 #4 #3 #2 #1 #0
3008 XSG
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 2 XSG A signal assigned to an X address is:
0: Fixed at the address.
1: Able to be reassigned to an arbitrary X address.
NOTE
When this parameter was set to 1, parameters No.
3013, No. 3014, No. 3012, and No. 3019 must be
set. If parameters No. 3013 and No. 3014 are not
set, the reference position return deceleration
signal is assigned to bit 0 of X0000. If parameters
No. 3012 and No. 3019 are not set, the skip to X0
signal, PMC axis control skip signal, measurement
position arrival signal, axis-direction-specific
manual feed interlock signal, and tool
compensation write signal are assigned to X0000.
3012 Skip signal assignment address
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Word path
[Valid data range] 0 to 727
Set an X address to which the skip signal (SKIPn) is to be assigned.
NOTE
This parameter is valid when bit 2 (XSG) of
parameter No. 3008 is set to 1.
Depending on the option configuration of the I/O
Link, the actually usable X addresses are:
X0 to X127, X200 to X327, X400 to X527, X600 to
X727