1.AXIS CONTROL B-63943EN-1/02
- 98 -
14988 Magnification for second cyclical pitch error compensation for each axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte axis
[Valid data range] 0 to 100
Set a magnification for second cyclical pitch error compensation for
each axis.
When 1 is set as the magnification for second cyclical pitch error
compensation, the unit of compensation data is the same as the
detection unit.
Caution
CAUTION
1 Using the appropriate parameters, set the number of
the most distant cyclic second pitch compensation
point on the - side of each axis and the number of
the most distant cyclic second pitch compensation
point on the + side of each axis. If the settings of
these two parameters are 0 or the same, cyclic
second pitch error compensation is not applied.
2 When interpolated pitch error compensation is used,
the pitch error compensation amount is output in
interpolated form in each cyclic second pitch error
compensation interval.
3 Cyclic second pitch error compensation is
superimposed even on rotation axis pitch error
compensation.
4 The sum of the compensation amounts per rotation
must always be set to 0.
5 Cyclic second pitch error compensation cannot be
used for an axis for which spindle positioning is
performed.
6 Cyclic second pitch error compensation is enabled
after a reference position return.
7 This function is optional function.
8 To use this function, the option for stored pitch error
compensation is required in addition to the option for
this function.