B-63943EN-1/02 13.PROGRAM COMMAND
- 1723 -
Do not enter an interrupt signal during execution of an interrupt
macro.
Signal
Interrupt signal for custom macro UINT<Gn053#3>
[Classification] Input signal
[Function] This signal calls and executes a program in memory.
During execution, a program in automatic operation is suspended.
To enable this signal to be accepted, a particular miscellaneous
function must be specified in a command program for automatic
operation. In addition, automatic operation must already be started to
accept this signal. The particular miscellaneous function code is set by
parameter Nos. 6003, 6033 and 6034.
Signal address
#7 #6 #5 #4 #3 #2 #1 #0
Gn053 UINT
Parameter
- Various Setting for Custom Macro
#7 #6 #5 #4 #3 #2 #1 #0
6003 MUS MSB MPR TSE MIN MSK
[Input type] Parameter input
[Data type] Bit path
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 1 MSK Absolute coordinates at that time during custom macro interrupt
0: Not set to the skip coordinates (system variables #5061 and later)
1: Set to the skip coordinates (system variables #5061 and later)
# 2 MIN Custom macro interrupt
0: Performed by interrupting an in-execution block (Custom macro
interrupt type I)
1: Performed after an in-execution block is completed (Custom
macro interrupt type II)
# 3 TSE Custom macro interrupt signal UINT
0: Edge trigger method (Rising edge)
1: Status trigger method
# 4 MPR Custom macro interrupt valid/invalid M code
0: M96/M97
1: M code set using parameters (Nos. 6033 and 6034)