B-63943EN-1/02 1.AXIS CONTROL
- 101 -
Parameters
10800 Axis for which three-dimensional error compensation is performed (1
st
axis)
10801 Axis for which three-dimensional error compensation is performed (2
nd
axis)
10802 Axis for which three-dimensional error compensation is performed (3
rd
axis)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte Path
[Valid data range] 1 – Max axes
Set three axes for which three-dimensional error compensation is
performed.
10803 Number of three-dimensional error compensation points (1
st
axis)
10804 Number of three-dimensional error compensation points (2
nd
axis)
10805 Number of three-dimensional error compensation points (3
rd
axis)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte Path
[Valid data range] 2 – 25
Set the number of three-dimensional error compensation points.
10806
Three-dimensional error compensation point number at the reference
position (1
st
axis)
10807
Three-dimensional error compensation point number at the reference
position (2
nd
axis)
10808
Three-dimensional error compensation point number at the reference
position (3
rd
axis)
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Input type] Parameter input
[Data type] Byte Path