B-63943EN-1/02-01
Edit
Apprv.
Design
Sheet
Title
Draw
No.
20/126
Date
Design
Descri
tion
Date
FANUC Se
ies 30i/31i/32i-
, 31i-
5
PMC Axis Control
2004.10.7
When bit 0 (RPD) of parameter No. 8002 is set to 1 (to use the PMC axis interface for rapid
traverse rate selection), the rapid traverse rate unit is 1 mm/min if bit 2 (R10) of parameter
No. 8005 is set to 0; the rapid traverse rate unit is 10 mm/min if bit 2 (R10) of parameter No.
8005 is set to 1.
With bit 2 (OVE) of parameter No. 8001, select a dry run signal and manual rapid traverse
selection signal to be used. The table below indicates the relationships between the bit
and signals.
Parameter OVE
(No.8001#2)
Dry run signal
Manual rapid traverse
selection signal
0
DRN(G0046.7) RT(G19.7)
1
EDRN(G150.7) ERT(G150.6)
When the dry run signal DRN/EDRN is set to 1, the feedrate is as indicated below.
When rapid traverse is specified Manual rapid traverse
selection signal
(RTorERT)
RDE(No.8001#3)=0 RDE(No.8001#3)=1
0
Rapid traverse Dry run feedrate
×*JV(NOTE)
1
Rapid traverse Rapid traverse
NOTE
When bit 1 (JOV) of parameter No. 1402 is set to 1, the manual
feedrate override signal *JV is not applied, but the dry run feedrate is
just applied.
Related parameters
Parameter DIAx (No.1006#3)
Parameter JOV (No.1402#1)
Parameter (No.1420)
Parameter OVE (No.8001#2)
Parameter RDE (No.8001#3)
Parameter RPD (No.8002#0)
Parameter CDI (No.8005#1)
Parameter R10 (No.8005#2)
Related signals
Manual rapid traverse selection signal RT (G19.7)
Dry run signal DRN(G46.7)
Manual rapid traverse selection signal (for PMC axis control) ERT (G150.6)
Dry run signal (for PMC axis control) EDRN (G150.7)