B-63943EN-1/02 17.PMC CONTROL FUNCTION
- 2047 -
End of macro program
(6) Please instruct M02 or M30 at the end of the macro program.
Moreover, please input external reset signal (ERS) or
reset&rewind signal (RRW) with M02 or M30 on the PMC side.
The program which had been selected before the macro was
executed is automatically selected by reset. The mode change
request signal(MCRQ) and mode notification signals are output
at the same time. At this time, the mode when macro call start
signal (MCSTx) is input is notified as the mode notification
signal.
Return of mode
(7) Please change the mode on the PMC side based on the signal
output in the step of above (6).
(8) Please set “1” in Mode change completion signal (MCFIN) on
the PMC side when the mode change is completed. On the CNC
side, the Mode change request signal (MCRQ), the Macro call
executing signal (MCEXE) and the Call program confirmation
signal(MCEXx) are set to “0” concurrently with asserting of the
Mode change completion signal (MCFIN). The PS5306 alarm is