16.MEASUREMENT B-63943EN-1/02
- 1858 -
#7 #6 #5 #4 #3 #2 #1 #0
6207 SFN
[Input type] Parameter input
[Data type] Bit path
# 2 SFN The feedrate used when the skip function based on high-speed skip
signals (with bit 1 (HSS) of parameter No. 6200 set to 1) or the
multi-skip function is being executed is:
0: Feedrate of a programmed F code.
1: Feedrate set in a parameter from parameter No. 6282 to No.
6285.
NOTE
For not the multi-stage skip function but the skip
function not using high-speed skip signals, see the
description of bit 1 (SFP) of parameter No. 6207.
6282 Feedrate for the skip function (G31, G31 P1)
6283 Feedrate for the skip function (G31 P2)
6284 Feedrate for the skip function (G31 P3)
6285 Feedrate for the skip function (G31 P4)
[Input type] Parameter input
[Data type] Real path
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the reference axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Each of these parameters sets a feedrate for each skip function G code.
These parameters are valid when bit 2 (SFN) of parameter No. 6207 is
set to 1.