1.AXIS CONTROL B-63943EN-1/02
- 186 -
- One-direction synchronization establishment
When synchronization error compensation is disabled,
synchronization establishment can be performed by setting bit 0
(SSO) of parameter No. 8305 to 1 to move the machine in one
direction along the master axis and slave axis. The move direction
depends on the reference position setting based on bit 0 (SSA) of
parameter No. 8304. When SSA = 0, for example, the machine
coordinate on the master axis or slave axis, whichever larger, is used
as the reference point. So, the machine moves in the + direction
along the axes.
When bit 1 (SSE) of parameter No. 8305 is set to 1, normal
synchronization establishment is performed instead of one-direction
synchronization establishment after an emergency stop.