B-63943EN-1/02 1.AXIS CONTROL
- 15 -
- Switching operation
According to the switching methods above, diameter/radius
specification is internally switched as described below.
1) Switching using a signal
- When parameter DIAx = 0 (radius specification) → Operation
is performed with diameter specification.
- When parameter DIAx = 1 (diameter specification) →
Operation is performed with radius specification.
2) Switching using a G code
- When the specified address value = 0 (radius specification) →
Operation is performed with radius specification.
- When the specified address value = 1 (diameter specification)
→ Operation is performed with diameter specification.
NOTE
1 When the diameter/radius specification switching state is
to be cancelled using a reset or mode switching at the
time of signal-based switching, the input signal needs to
be operated.
2 Switching using a G code is cancelled by a reset.
Signal
Diameter/radius specification switch signals DI1 to DI8<Gn296>
[Classification] Input signal
[Function] Switches between diameter specification and radius specification for
each axis.
[Operation] When a diameter/radius specification switch signal is set to 1,
diameter/radius specification operates as follows:
The specification set by bit 3 (DIAx) of parameter No. 1006 is
reversed.
Diameter/radius specification switching in-progress signal DM1 to DM8<Fn296>
[Classification] Output signal
[Function] Notifies that each axis is in diameter/radius specification switching
operation.
[Output condition] A diameter/radius specification switching in-progress signal is set to 1
in the following case:
- When the diameter/radius specification of the corresponding axis
has been switched
(when the specification method set by parameter DIAx is
reversed for operation)
A diameter/radius specification switching in-progress signal is
set to 0 in the following case:
- When the diameter/radius specification of the corresponding axis
is not switched
(when the specification method set by parameter DIAx is used
for operation)