1.AXIS CONTROL B-63943EN-1/02
- 138 -
#7 #6 #5 #4 #3 #2 #1 #0
1905 PM2 PM1 PM4 PM3
[Input type] Parameter input
[Data type] Bit axis
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
# 1 PM3 The third separate detector interface unit is:
0: Not used.
1: Used.
# 2 PM4 The fourth separate detector interface unit is:
0: Not used.
1: Used.
# 6 PM1 The first separate detector interface unit is:
0: Not used.
1: Used.
# 7 PM2 The second separate detector interface unit is:
0: Not used.
1: Used.
NOTE
When automatic setting mode is selected for FSSB
setting (when the parameter FMD (No.1902#0) is
set to 0), this parameter is automatically set when
input is performed with the FSSB setting screen.
When manual setting 2 mode is selected for FSSB
setting (when the parameter FMD (No.1902#0) is
set to 1), this parameter must be set directly. When
a separate detector interface unit is used, a
connector number must be set in the
corresponding parameter (No.1936, No.1937,
No.1938, or No.1939).
1936 Connector number of the first separate detector interface unit
1937 Connector number of the second separate detector interface unit
1938 Connector number of the third separate detector interface unit
1939 Connector number of the fourth separate detector interface unit