11.SPINDLE SPEED FUNCTION B-63943EN-1/02
- 1508 -
Signal
Simple spindle synchronous control signal ESRSYC<Gn064#6>
[Classification] Input signal
[Function] This signal specifies switching to the simple spindle synchronous
control mode for the first/second spindles.
[Operation] When this signal is set to 1, the simple spindle synchronous control
mode for the first/second spindles is set.
When this signal is set to 0, the simple spindle synchronous control
mode for the first/second spindles is canceled.
This signal is valid only when bit 5 (SSY) of parameter No. 3704 is
set to 0.
Simple spindle synchronous control signal for each spindle
ESSYC1<Gn264#0> : For first spindle
ESSYC2<Gn264#1> : For second spindle
ESSYC3<Gn264#2> : For third spindle
ESSYC4<Gn264#3> : For fourth spindle
[Classification] Input signal
[Function] These signals specify switching to the simple spindle synchronous
control mode for each spindle.
[Operation] When each of these signals is set to 1, the simple spindle synchronous
control mode with the corresponding spindle set as a slave spindle is
set.
When each of these signals is set to 0, the simple spindle synchronous
control mode with the corresponding spindle set as a slave spindle is
canceled.
When ESSYC1 is se to 1: Simple spindle synchronous control with
the first spindle set as a slave spindle is exercised.
When ESSYC2 is se to 1: Simple spindle synchronous control with
the second spindle set as a slave spindle is exercised.
When ESSYC3 is se to 1: Simple spindle synchronous control with
the third spindle set as a slave spindle is exercised.
When ESSYC4 is se to 1: Simple spindle synchronous control with
the fourth spindle set as a slave spindle is exercised.
These signals are valid only when bit 5 (SSY) of parameter No. 3704
is set to 1.
Which spindle is synchronized with which spindle is set using
parameter No. 4821.
First simple spindle synchronous parking signal PKESS1<Gn122#6> or PKESS1<Gn031#6>
[Classification] Input signal
[Function] This signal parks the first spindle in simple spindle synchronous
control.
[Operation] When this signal is set to 1, the first spindle is placed in the parking
state.
When this signal is set to 0, the parking state of the first spindle is
canceled.
When bit 7 (SPK) of parameter No. 4800 is set to 1, <G031#6> is
used.
This signal is valid only when bit 5 (SSY) of parameter No. 3704 is
set to 0.