4.REFERENCE POSITION ESTABLISHMENT B-63943EN-1/02
- 486 -
+J1 or -J1
Grid
Manual reference position return
mode
.
.
.
P1
Ref.P2 P3 P4
Set bit 4 (APZx) of parameter
No. 1815 to 1 at this position.
Put the system in the MDI mode at point Ref used as the reference
position and set bit 4 (APZx) of parameter No. 1815 to 1.
Then, turn the power off, then on again. The correspondence
between the machine position and position in the absolute-position
detector has been established.
Parameter
#7 #6 #5 #4 #3 #2 #1 #0
1002 IDG
[Input type] Parameter input
[Data type] Bit path
# 7 IDG When the reference position is set without dogs, automatic setting of
the IDGx parameter (bit 0 of parameter No.1012) to prevent the
reference position from being set again is:
0: Not performed.
1: Performed.
NOTE
When this parameter is set to 0, bit 0 (IDGx) of
parameter No. 1012 is invalid.
#7 #6 #5 #4 #3 #2 #1 #0
1005 DLZx
[Input type] Parameter input
[Data type] Bit axis
# 1 DLZx Function for setting the reference position without dogs
0: Disabled
1: Enabled