3.MANUAL OPERATION B-63943EN-1/02
- 418 -
1424 Manual rapid traverse rate for each axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Set the rate of manual rapid traverse when the rapid traverse override
is 100% for each axis.
NOTE
1 If 0 is set, the rate set in parameter 1420 (rapid
traverse rate for each axis) is assumed.
2 When manual rapid traverse is selected (bit 0 (RPD)
of parameter No. 1401 is set to 1), manual feed is
performed at the feedrate set in this parameter,
regardless of the setting of bit 4 (JRV) of parameter
No. 1402.
#7 #6 #5 #4 #3 #2 #1 #0
1610 JGLx
[Input type] Parameter input
[Data type] Bit axis
# 4 JGLx Acceleration/deceleration in jog feed
0: Exponential acceleration/deceleration is applied.
1: (depending on which is used for cutting feed. (depending on the
setting in CTBx or CTLx, bit 1 or 0 of parameter No.1610)
1624 Time constant of acceleration/deceleration in jog feed for each axis.
[Input type] Parameter input
[Data type] Word axis
[Unit of data] msec
[Valid data range] 0 to 4000
Set the time constant used for acceleration/deceleration in jog feed
for each axis.
1625 FL rate of exponential acceleration/deceleration in jog feed for each axis
[Input type] Parameter input
[Data type] Real axis
[Unit of data] mm/min, inch/min, degree/min (machine unit)
[Minimum unit of data] Depend on the increment system of the applied axis
[Valid data range] Refer to the standard parameter setting table (C)
(When the increment system is IS-B, 0.0 to +240000.0)
Set the FL rate of exponential acceleration/deceleration in cutting feed
for each axis. This parameter allows only the exponential type.