4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 136 -
#7 #6 #5 #4 #3 #2 #1 #0
1804 SAK ANA IVO BLC
[Data type] Bit axis
BLC During circular interpolation by jog feed (manual circular
interpolation function), the backlash acceleration function is:
0 : Disabled.
1 : Enabled.
IVO When an attempt is made to release an emergency stop while the
VRDY OFF alarm ignore signal is 1:
0 : The emergency stop state is not released until the VRDY OFF
alarm ignore signal is set to 0.
1 : The emergency stop state is released.
NOTE
When a reset is issued while the VRDY OFF alarm
ignore signal is set to 1 and the motor activating
current is low, the reset state can also be released,
provided this parameter is set to 1.
ANA When an unexpected disturbance torque is detected for an axis:
0 : Movement along all axes is stopped, and a servo alarm is output.
1 : No servo alarm is output, and movement along only the axes of
the group containing the axis with the unexpected disturbance
torque is stopped in interlock mode. (The group number of each
axis is set in parameter No.1881.)
SAK When the VRDY OFF alarm ignore signal IGNVRY is 1, or when the
VRDY OFF alarm ignore signals IGVRY1 to IGVRY8 are 1:
0 : Servo ready signal SA is set to 0.
1 : Servo ready signal SA remains set to 1.
#7 #6 #5 #4 #3 #2 #1 #0
1805 TQU
[Data type] Bit
TQU If follow-up is not performed by the torque control command of PMC
axis control, the servo error counter is:
0 : Updated.
1 : Not updated.
NOTE
1 This parameter is valid if follow-up is not performed
(bit 4 (TQF) of parameter No. 1803 is set to 0).
2 When torque control is switched to position control,
a reference position return must be made.