4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 228 -
3218
Program number to be registered in input/output simultaneous operation
(4-digit program number)
[Data type] Word
[Valid data range] 1 to 9999
When a program entered through the input/output unit is executed and
registered in memory at the same time in input/output simultaneous
operation, this parameter sets a program number for that program.
NOTE
1 If a value that falls outside the valid data range is
specified, the number of the input program is used
as is as the registered program number.
2 When the 8-digit program number function is used,
use parameter No.3219 instead of parameter
No.3218.
3219
Program number to be registered in synchronous input/output operation
(8-digit program number)
[Data type] 2-word
[Valid data range] 0 to 99999999
When a program entered through the input/output unit is executed and
registered in memory at the same time in synchronous input/output
operation, this parameter sets a program number for that program.
NOTE
1 If a value that falls outside the valid data range is
specified, the number of the input program is used
as is as the registered program number.
2 When the 8-digit program number function is not
used, use parameter No.3218 instead of parameter
No.3219.