B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 665 -
4.89 PARAMETERS OF STRAIGHTNESS COMPENSATION (2
OF 2)
13301 Compensation point number a of move axis 4
13302 Compensation point number b of move axis 4
13303 Compensation point number c of move axis 4
13304 Compensation point number d of move axis 4
13311 Compensation point number a of move axis 5
13312 Compensation point number b of move axis 5
13313 Compensation point number c of move axis 5
13314 Compensation point number d of move axis 5
13321 Compensation point number a of move axis 6
13322 Compensation point number b of move axis 6
13323 Compensation point number c of move axis 6
13324 Compensation point number d of move axis 6
NOTE
1 When these parameters are set, the power must be
turned off before operation is continued.
2 Parameters No. 13301 to No. 13324 are valid only
when bit 1 (ST6) of parameter No. 5700 is set to 1.
[Data type] Word
[Unit of data] Number (compensation point number in stored pitch error
compensation)
[Valid data range] 0 to 1023
These parameters set four compensation points for each axis.