B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 651 -
Maximum manual handle feedrate 4 for each axis
12753
[Data type] Word axis
[Unit of data, valid data range]
Valid data range
Increment system Units of data
IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotary axis 1 deg/min 6 to 15000 6 to 12000
Set a maximum manual handle feedrate for each axis.
External deceleration rate 5 in cutting feed
12754
[Data type] Word
[Unit of data, valid data range]
Valid data range
Increment system Units of data
IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Set external deceleration rate for cutting feed.
External deceleration rate 5 for each axis in rapid traverse
12755
[Data type] Word axis
[Unit of data, valid data range]
Valid data range
Increment system Units of data
IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotary axis 1 deg/min 6 to 15000 6 to 12000
Set external deceleration rate for each axis in rapid traverse.
Maximum manual handle feedrate 5 for each axis
12756
[Data type] Word axis
[Unit of data, valid data range]
Valid data range
Increment system Units of data
IS-B IS-C
Metric machine 1 mm/min 6 to 15000 6 to 12000
Inch machine 0.1 inch/min 6 to 6000 6 to 4800
Rotary axis 1 deg/min 6 to 15000 6 to 12000
Set a maximum manual handle feedrate for each axis.