4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 406 -
4.36 PARAMETERS OF STRAIGHTNESS COMPENSATION (1
OF 2)
#7 #6 #5 #4 #3 #2 #1 #0
5700 SMT ST6 RTS
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
RTS When compensation is rewritten for the straightness compensation
function, it is enabled:
0 : After power-off.
1 : Immediately.
When this function is enabled, no power-off alarm is issued even if
compensation parameters for straightness compensation (No. 5761 to
No. 5784) are rewritten.
ST6 Combination of moving axis and compensation axis is:
0 : 3 combinations
1 : 6 combinations
SMT Parameters (No.13391 to No.13396) for straightness compensation
magnification
0 : Are effective only for the first moving axis when two or more
moving axes are set using the same axis number.
1 : Are effective for the respective moving axes even when two or
more moving axes are set using the same axis number.