4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 604 -
#7 #6 #5 #4 #3 #2 #1 #0
8516 HB8 HB7 HB6 HB5 HB4 HB3 HB2 HB1
#7 #6 #5 #4 #3 #2 #1 #0
8517 HBG HBF HBE HBD HBC HBB HBA HB9
[Data type] Bit
HB1 to HBG The signal is turned off when the corresponding high-speed position
switch passes through the machine coordinate position set in
parameter No. 8590 to 8599 or 12241 to 12246:
0 : In the negative (-) direction.
1 : In the positive (+) direction.
Bit name HB1 to HBG corresponds to the high-speed position switch
place.
When direction-dependent type is selected for the output type of a
high-speed position switch in parameter No. 8508 or 8509, the
corresponding parameter sets the direction.
8565 Output address of the high-speed position switch signal
NOTE
When this parameter is set, the power must be
turned off before operation is continued.
[Data type] Word
[Valid data range] 0, 1 to 126, 1000 to 1014, 1020 to 1034