4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 602 -
4.72 PARAMETERS OF HIGH-SPEED POSITION SWITCH (1 OF
2)
#7 #6 #5 #4 #3 #2 #1 #0
8500 EPS
[Data type] Bit
EPS The maximum number of high-speed position switches is:
0 : 6.
1 : 16.
#7 #6 #5 #4 #3 #2 #1 #0
8501 HPT HPE HPO
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
HPO The output signal of a high-speed position switch is output to:
0 : Address Y. (See the explanation of parameter No. 8565.)
1 : Address F. (PMC signals <F293 or F294>)
HPE The current position used with the high-speed position switch of
decision-by-direction type:
0 : Considers a servo error.
1 : Does not consider a servo error.
HPT A direction-dependent type high-speed position switch is switched:
0 : When a reference machine coordinate is passed.
1 : When a reference machine coordinate is reached.
#7 #6 #5 #4 #3 #2 #1 #0
8504 HE8 HE7 HE6 HE5 HE4 HE3 HE2 HE1
#7 #6 #5 #4 #3 #2 #1 #0
8505 HEG HEF HEE HED HEC HEB HEA HE9
[Data type] Bit
HE1 to HEG The corresponding high-speed position switch is:
0 : Enabled.
1 : Disabled.
1 to G of a bit name corresponds to the high-speed position switch
place.
These parameters specify whether to enable or disable the
corresponding high-speed position switches.
A disabled high-speed position switch always outputs 0.