4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 660 -
4.88 PARAMETERS OF TOOL MANAGEMENT FUNCTIONS
#7 #6 #5 #4 #3 #2 #1 #0
13200 NFD NAM T0O TP2 ETE TRT THN TCF
[Data type] Bit
TCF When a T code is specified with the tool management function:
0 : A cartridge number and pot number found by the NC are output.
1 : The specified T code is output without modification.
THN When NX.T and HD.T are displayed with the tool management
function:
0 : The tool type numbers at the first spindle position and the first
standby position are displayed.
1 : The values specified from the PMC window are displayed.
TRT As the remaining lifetime value for outputting the tool life arrival
notice signal:
0 : The remaining lifetime of the last tool is used.
1 : The sum of the remaining lifetimes of the tools with the same
type number is used.
NOTE
This parameter is valid when bit 3 (ETE) of
parameter No. 13200 is set to 0 (arrival notice for
each type number).
ETE The tool life arrival notice signal is output:
0 : For each tool type.
1 : For each tool.
TP2 The punch-out format of cartridge management data is:
0 : New registration format (G10L76P1 format).
1 : Modification format (G10L76P2 format).
T0O When T0 is specified:
0 : A tool search is made assuming that the tool type number is 0.
1 : The cartridge number and pot number are assumed to be 0.
NAM When a T code is specified, but a valid tool with a remaining lifetime
cannot be found:
0 : The alarm (PS5317) "LIVES OF ALL TOOLS EXPIRED" is
issued.
1 : The alarm is not issued. Instead, the tool with the maximum tool
management number is selected from the tools of the specified
tool type, and TMFNFD<F315#6> is set to 1.
NFD When a T code is specified, but a valid tool with a remaining lifetime
cannot be found in the cartridge:
0 : The spindle position and standby position are also searched.
1 : The spindle position and standby position are not searched.