4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 432 -
#7 #6 #5 #4 #3 #2 #1 #0
6208
9S8 9S7 9S6 9S5 9S4 9S3 9S2 9S1
[Data type] Bit
9S1 to 9S8 Specify which high-speed skip signal to be enabled for the continuous
high-speed skip command G31P90 or the EGB skip command G31.8.
The bits correspond to signals as follows:
9S1 HDI0
9S2 HDI1
9S3 HDI2
9S4 HDI3
9S5 HDI4
9S6 HDI5
9S7 HDI6
9S8 HDI7
Set each bit as follows:
0 : The corresponding skip signal is invalid.
1 : The corresponding skip signal is valid.
#7 #6 #5 #4 #3 #2 #1 #0
ROS
6210
ASB ASL ROS CS3
[Data type] Bit
CS3 As the continuous high-speed skip command:
0 : G31 P90 is used.
1 : G31.9 is used.
With G31 P90, when a high-speed skip signal is input, the absolute
coordinates are stored in custom macro variables #5061 through
#5068. When the next high-speed skip signal is input, these variables
are updated. With G31.9, when a high-speed skip signal is input, the
absolute coordinates are sequentially stored in the custom macro
variables specified in the G31.9 block.
ROS When the skip position goes beyond the roll-over range, the values of
system variables #5061 through #5068 indicating the skip signal
position:
0 : Are not rolled over.
1 : Are rolled over similar to the absolute coordinates.