B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 249 -
4.22 PARAMETERS OF PITCH ERROR COMPENSATION
#7 #6 #5 #4 #3 #2 #1 #0
EPC
3601
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
EPC The pitch error compensation on an axis of Cs contour control on the
slave side during spindle simple synchronous control is:
0 : The same as that on the master axis.
1 : Just for the slave axis.
To use unique pitch error compensation, set a pitch error
compensation data number in parameters No. 3661 to 3674, and set
the specified pitch error compensation data to desired unique pitch
error compensation.
If bit 0 (BDP) of parameter No. 3605 is set to use bi-directional pitch
error compensation, set parameters No. 3676 to 3684 as well.
#7 #6 #5 #4 #3 #2 #1 #0
3605 ROPx ISTx IIPx BDPx
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit axis
BDPx Bi-directional pitch error compensation is:
0 : Not used.
1 : Used.
NOTE
1 The function of bi-directional pitch error
compensation is required.
2 The function of stored pitch error compensation is
required.