B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 211 -
Axis display order for current position display screens
3130
[Data type] Byte axis
[Valid data range] 0, 1 to the number of controlled axes
This parameter specifies the order in which axes are displayed on the
current position display screens (absolute, relative, overall, and handle
interrupt screens) during two-path control when the seven-soft key
type display unit is used.
NOTE
This parameter is valid only for the common
screens for two-path control. Axes are displayed in
the order of their axis numbers on individual
screens for each path and two-path simultaneous
display screens.
3131 Subscript of each axis name
[Data type] Byte axis
This parameter specifies a subscript (one character) of each axis name
with a code.
An axis name is followed by a subscript (one character) specified by
this parameter.
For example, this parameter can be used to identify which path the
coordinate of an axis displayed on the current position display screen
belongs to.
NOTE
1 When multi-path control is used, set this parameter
for each path.
2 For characters and codes, see the correspondence
table in Appendix A.
3 If the character code 0 is set when multi-path
control is used, each path number is displayed as a
subscript.
[Example] When the configuration of axes is X, Z, C and Y in path 1 and X, Z,
and B in path 2
(1) Setting for path 1
Parameter 3131x 65 (A)
Parameter 3131z 49 (1) XA, Z1, CS, and Y1 are
Parameter 3131c 83 (S) displayed as axis names.
Parameter 3131y 0 (1)
(2) Setting for path 2
Parameter 3131x 66 (B) XB, Z2, and B are
Parameter 3131z 0 (2) displayed as axis names.
Parameter 3131b 32 (space)