4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 240 -
QAB When the passing-point signal output function is used, address ",Q"
specifies:
0 : Remaining distance to be traveled
1 : Coordinate value of the longest axis
#7 #6 #5 #4 #3 #2 #1 #0
C07 C05 C04 C03 C02 C01
3406
C07 C05 C04 C03 C02 C01
#7 #6 #5 #4 #3 #2 #1 #0
C14 C11 C10 C08
3407
C15 C14 C13 C11 C10 C09 C08
#7 #6 #5 #4 #3 #2 #1 #0
C16
3408
C20 C19 C18 C17 C16
#7 #6 #5 #4 #3 #2 #1 #0
CFH
3409
CFH C24
[Data type] Bit
Cxx (xx: 01 to 24) When bit 6 (CLR) of parameter No.3402 is 1, the reset button on the
MDI panel, the external reset signal, the reset and rewind signal, or
emergency stop will,
0 : Clear the G code with group number xx.
1 : Not clear the G code with group number xx.
CFH When bit 6 (CLR) of parameter No.3402 is 1, the
RESET
key on the
MDI panel, the external reset signal, the reset and rewind signal, or
emergency stop will,
0 : Clear F codes, H codes (for the M series), D codes (for the M
series), and T codes (for the T series).
1 : Not clear F codes, H codes (for the M series), D codes (for the M
series), and T codes (for the T series).