B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 571 -
4.68 PARAMETERS OF SIMPLE SYNCHRONOUS CONTROL
#7 #6 #5 #4 #3 #2 #1 #0
8301
SOF SC2 SYE SYA
[Data type] Bit
SYA In the servo-off state in simple synchronous control, the limit of the
difference between the position deviation of the master axis and that
of the slave axis is:
0 : Not checked.
1 : Checked.
SYE During execution of synchronous control, the limit of the difference
between position deviations (parameters No. 8313 or No. 8323) is:
0 : Checked.
1 : Not checked.
SC2 When the synchronous positioning function for simple synchronous
control is used:
0 : Servo alarm No. 410 is issued if the position deviation at the time
of synchronous positioning operation is greater than the value set
in parameter No. 8315 or parameter No. 8325.
1 : Servo alarm No. 407 is issued if the amount of synchronous
positioning is greater than the value set in parameter No. 8315 or
parameter No. 8325.
SOF The synchronization compensation function in simple synchronous
control (one pair) is:
0 : Not used.
1 : Used.
#7 #6 #5 #4 #3 #2 #1 #0
8302
SMA SSE ATS ATE
NOTE
When at least one of these parameters is set, the
power must be turned off before operation is
continued.
[Data type] Bit
ATE Automatic setting of grid positioning for simple synchronous control
(one pair) is:
0 : Disabled
1 : Enabled