B-63530EN/03 4.DESCRIPTION OF PARAMETERS
- 631 -
4.78 PARAMETERS OF SUPERIMPOSED COMMAND
FUNCTION IN BINARY OPERATION
12250 Superimposed pulses in binary operation (numerator)
12251 Superimposed pulses in binary operation (denominator)
[Data type] Word axis
[Valid data range] -32768 to 32767
These parameters specify a superimposed pulse value for the
superimposed specification function in binary operation for each axis.
If 0 is set in parameter No. 12251, superimposed is not performed.
[Example] When the superimposed pulse value for one distribution operation is
0.4
Parameter No.12250=2
Parameter No.12251=5
First distribution: 2/5 pulse → Output 0
Second distribution: 4/5 pulse → Output 0
Third distribution: 6/5 pulse → Output 1 (1/5 pulse remaining)
Fourth distribution: 3/5 pulse → Output 0
Fifth distribution: 5/5 pulse → Output 1 (0/5 pulse remaining)
: : :
12252 Superimposed pulse travel distance in binary operation
[Data type] 2-word axis
[Valid data range] -99999999 to 99999999
This parameter sets a superimposed pulse travel distance for the
superimposed specification function in binary operation.
NOTE
1 If 0 is set in this parameter, superimposed control
is not performed.
2 This parameter is valid from the start of a binary
operation until the binary operation ends. If this
parameter is rewritten during a binary operation,
the new parameter value becomes valid starting
with the next binary operation.