4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 546 -
MCDx The axes to be replaced with each other under composite control have
the coordinate systems placed:
0 : In the same direction. Simple composite control is applied. (The
axes of tool posts 1 and 2 move in the same direction.)
1 : In opposite directions. Mirror-image composite control is applied.
(The axes of tool posts 1 and 2 move in opposite directions.)
This parameter determines the direction in which an axis moves. The
parameter is also used to automatically set the coordinate system when
composite control is started or terminated.
X1 X2
Z1 Z2
MCD(z) MCD(x)
0 0
X1
Z1
X2
Z2
MCD(z) MCD(x)
0 1
X2
Z2
Z2
X2
Z1
X1
X1
Z1
MCD(z) MCD(x)
1 0
MCD(z) MCD(x)
1 1
MUMx In composite control, a move command for the axis:
0 : Can be specified.
1 : Cannot be specified.
NOTE
Upon the execution of a move command along an
axis for which MUMx is set to 1 during composite
control, alarm P/S No.226 is issued.