4.DESCRIPTION OF PARAMETERS B-63530EN/03
- 234 -
IWZ Setting a workpiece origin offset value or workpiece coordinate
system shift value (T series) by MDI key input in the automatic
operation activation or halt state is:
0 : Not disabled
1 : Disabled
MCM The setting of custom macro vaiables by MDI key operation is:
0 : Enabled regardless of the mode.
1 : Enabled only in the MDI mode.
KEY For memory protection keys:
0 : The KEY1, KEY2, KEY3, and KEY4 signals are used.
1 : Only the KEY1 signal is used.
NOTE
The functions of the signals depend on whether
KEY=0 or KEY=1.
When KEY = 0:
- KEY1 : Enables tool offset value, workpiece origin
offset value, and workpiece coordinate
system shift value (T series) to be input.
- KEY2: Enables setting data, macro variables, and
tool life management data to be input.
- KEY3: Enables program registration and editing.
- KEY4: Enables PMC data (counter and data
table) to be input.
When KEY = 1:
- KEY1 : Enables program registration and editing,
and enables PMC data.
- KEY2 to KEY4: Not used
#7 #6 #5 #4 #3 #2 #1 #0
3291 WPT
[Data type] Bit
WPT The input of the tool wear compensation amount is:
0 : Enabled according to memory protection key signal KEY1.
1 : Always enabled.
#7 #6 #5 #4 #3 #2 #1 #0
3292 PK5
[Data type] Bit
PK5 The KEYPRM signal (memory protection signal, parameter write
setting) is:
0 : Disabled.
1 : Enabled.
When this parameter is set to 1, PWE on the setting screen is invalid,
and memory protection/parameter write setting is performed with the
KEYPRM signal<G046#0>.